Heures d'ouverture:Lun - Sam 8.00 - 18.00 Appelez-nous:(+212) 661 257 892

Débitmètres à ultrasons

Mesure de débit facile et précise sans interrompre le processus
Débitmètres à ultrasons
Capteur de type à pince facilement montable sur un tuyau existant
Convient à une large gamme de liquides, par exemple, eau déminéralisée, eau de refroidissement, solution chimique, eau potable, eau de mer, huile, eau du robinet, eau chaude, eau industrielle, liquides corrosifs.
Un débitmètre à ultrasons pour l’air est également disponible

Compact and handy

  • High accuracy ±1.0% of rate and fast response ≤ 1 s
  • A wide variety of detectors
  • Tolerant to bubbles
  • Battery-powered, for 12 hours
  • Data storage on SD card
  • USB port for connection with PC
  • Consumed energy calculation
  • Printer (option)
  • Flow velocity profile (option)

Consumed Energy Calculation

A function to obtain thermal energies exchanged via
fluid used in air-conditioning systems.
The transmitter calculates the consumed thermal
energy based on the forward flow temperature,
the return flow temperature,
and the flow rate.

Specifications

Fluid Uniform liquid through which ultrasonic wave can propagate (water, distilled water, alcohol, etc.)
Pipe inner diameter 13–6000 mm (depends on detector)
Fluid temperature -40°C to +200 °C (depends on detector)
Velocity 0 to ±32 m/s (minimum ±0.3 m/s)
Accuracy ±1.0% of rate (depends on flow rate)
Output cycle 1 s
Path 1 path, transit time method
Display Color LCD with back light
Analog output 4–20 mA DC (1 point)
Analog input 4–20 mA DC/1–5 V DC (2 points)
Power supply voltage Built-in battery, (12 hours of continuous operation)
Enclosure IP64
Dimensions 210 × 120 × 65 mm
Weight Approx. 1kg
SD card (option) Data of 2-years worth can be stored in 512 MB card.
Serial communication Data in SD card (instantaneous values, integrated values) can be transmitted to PC
USB cable: maximum 3 m
Functions Damping time constant (0–100 s)
Instantaneous value display (10 digits) Various flow rate unit settable
Total value display (10 digits) Various flow rate unit settable
Consumed heat quantity computation
Self diagnosis (battery voltage drop and received waveform from the sensor)
Flash memory (parameters of pipe, fluid, sensor, etc)
Number of registration sites: 32
Zero point adjustment (by setting/clearing zero)
Graph view, waveform view
Bi-directional flow measurement
Low-flow cutoff (0–5 m/s)
Option Printer: screen hard copy, periodic printing and logged data printing
Detector for flow velocity profile measurement: displays flow velocity profile of instantaneous value and average value

    Reviews

    There are no reviews yet.

    Be the first to review “Débitmètres à ultrasons”

    industrie

    Qualistar sarl

    Créer de l’énergie et à construire l’environnement de demain.
    (+212) 661 257 892

    www.qualistar-instrument.com

    contact@qualistar-instrument.com

    rester en contact

    Suivez Nous

    Amélioration de stratégie globale, l’expertise technique, la coopération et l’innovation.